| |  | | | | Commercial Air Cleaning Systems > Honeywell Ceiling Mounted F90A |  | | The F90A Suspend Mount Electronic Air Cleaner handles the air filtration needs of a larger area. A three speed fan switch lets you increase or decrease the amount of air to match the level of indoor air pollutants. Optional wired or Wireless remote control makes changing speeds even easier. Thanks to the Coanda airflow pattern air cleaner is re-circulated throughout the room. Special features built into the F90A ensures reliable operation a solid state power supply for consistent voltage output, built-in performance indicator, a high/low performance switch. The F90A features an attractive, clean appearance to coordinate with any room décor. | - | 3 or 5 speed motor driven fan circulates up to 1250 cfm (2100 m³/hr) | - | Removes up to 95% of staining dirt from air | - | Heavy duty commercial cells and prefilter are removable for cleaning | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Provides Coanda air distribution (recirculation of clean air in 6 |
| direction) | - | LEDs indicate ON and CHECK | - | 3-position adjustable discharge louvers | - | Available with gray finish or woodgrain with black trim | - | Infrared remote control with self diagnostic function available | | Technical Specifications : | | | | | | Honeywell | | | F90A | | | Ceiling Mounted | | | Yes / No (Selectable) | | | 1250 cfm (2100m³/hr) | | | Up to 95% ASHRAE 52-1-1992 | | | 220-240V 50/60Hz, Max 270W | | | White / Black with wood Grain Panel | | | 743(W) x 743(H) x 324(D) | | | 29.5 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL, CSA, Canadian EMI Certified, CE applicable | | | | | | Commercial Air Cleaning Systems > Honeywell Ceiling Mounted F90B |  | | The F90B Portable Electronic Air Cleaner handles the air filtration needs of a larger area. A three speed fan switch lets you increase or decrease the amount of air to match the level of indoor air pollutants. Optional wired or Wireless remote control makes changing speeds even easier. Thanks to the Coanda airflow pattern air cleaner is re-circulated throughout the room. Special features built into the F90B ensures reliable operation a solid state power supply for consistent voltage output, built-in performance indicator, a high/low performance switch. The F90B features an attractive, clean appearance to coordinate with any room décor. It's portable. | - | 3 or 5 speed motor driven fan circulates up to 590 cfm (1000 m³/hr) | - | Removes up to 95% of staining dirt from air | - | Heavy duty commercial cells and prefilter are removable for cleaning | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Provides Coanda air distribution (recirculation of clean air in 6 |
| direction) | - | LEDs indicate ON and CHECK | - | 3-position adjustable discharge louvers | - | Available with gray finish or woodgrain with black trim | - | Infrared remote control with self diagnostic function available | | Technical Specifications : | | | | | Honeywell | | | F90B | | | Ceiling Mounted or Floor Standing | | | Yes / No (Selectable) | | | 590 cfm (1000 m³/hr) | | | Up to 95% ASHRAE 52-1-1992 | | | 220-240V 50/60Hz, Max 115W | | | Black with wood grain panel | | | 489(W) x 743(H) x 324(D) | | | 16.2 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL, CSA, Canadian EMI Certified, CE applicable | | | | | | Commercial Air Cleaning Systems > Honeywell Ceiling Flush Mounted F57A |  | | Specially designed for drop ceilings, the F57A is ideal for large spaces. Suitable for use in Lounges, Bars, Conference rooms, Office, Restaurants and others. With the compact size it only require 13 ½ inches of clearance above. The F57A operates at your choice of speeds-HIGH, MEDIUM or LOW using push button on the front panel of the unit. Other convenient control options include remote control and wireless remote control. A solid state power supply for consistent voltage output, built in performance indicator, high/low performance switch, commercial duty air cleaner cells and maintenance free motor with sealed bearings all work together to ensure maximum reliability. | - | 3-speed motor-driven fan circulates up to 875 cfm (1500 m³/hr) | - | Heavy duty commercial cells and prefilter are removable for cleaning | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Provides Coanda air distribution (recirculation of clean air in 6 |
| direction) | - | LEDs indicate ON and CHECK | - | Selectable infrared remote control models for easy operation | | Technical Specifications : | | | | | Honeywell | | | F57A | | | Ceiling Mounted | | | Yes / No (Selectable) | | | 875 cfm (1500 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V/50Hz, Max 315W | | | White | | | 1168(W) x 559(H) x 343(D) | | | 37.6 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL, CSA, CE Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Ceiling Flush Mounted F57B |  | | The only thing small about F57B is its size. Built to the same demanding performance specification as the larger F57A, this smaller unit slips into any 2 by 2 foot space in the drop ceilings. It requires only 13 ½ inches of ceiling clearance above. The F57B is the space saving way to improve air quality in a smaller room. F57B captures a minimum of 94% of particles ( 0.5 micron or Larger ) from the air passing through its cells. It then re-circulates cleaner air through out the room using Coanda air flow pattern. Optional carbon filters are available to help. | | 3-speed motor-driven fan circulates up to 460 cfm (780 m³/hr) | | Available in 220-240 Vac 50 Hz | | Heavy duty commercial cells and prefilter are removable for cleaning | | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | | Provides Coanda air distribution (recirculation of clean air in 6 |
| direction) | | LEDs indicate ON and CHECK | | Selectable infrared remote control models for easy operation | | Technical Specifications : | | | | | Honeywell | | | F57B | | | Ceiling Mounted | | | Yes / No (Selectable) | | | 460 cfm (780 m³/hr) | | | Up to 95% ASHRAE 52-1-1992 | | | 220-240V/50Hz, Max 275W | | | White | | | 572(W) x 572(H) x 342(D) | | | 24.5 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL, CSA, CE Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Return Grille Mounted F52G |  | | The F52G Flush Mount Electronic Air Cleaner are ceiling mounted as a return air grill. Designed for use as a return air grille. It removes air borne contamination such as Tobacco smoke, dust mites, Mold spores, Bacteria, Mites Antigen, cat danders, Pollens and more. Honeywell Model F52G is design for free air return and ducted Air conditioning system. | | Models available with one electronic cell and a rated capacity 1000 |
| cfm (1700 m³/hr) | | Solid state power supply energized by ON/OFF switch; or |
| interconnection to fan coil system if required | | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | | Pressure drop approximately equal to that of regular fiberglass filter | | Built-in light in the switch shows that air cleaner is operating | | Automatic interlock switch disconnects the power when unit is opened | | Intelligent fan speed detection allows easy interconnection with FCU |
| thermostat | | Technical Specifications : | | | | | Honeywell | | | F52G | | | Return Grille Mounted | | | Yes / No (Selectable) | | | 1000 cfm (1700 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V/50Hz, Max 72W | | | White | | | 600(W) x 600(H) x 442(D) | | | 14 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Return Grille Mounted F58G |  | | The F58G Duct / AHU Mount Electronic Air Cleaner. The Honeywell Model F58G is design for compact and easy installation. This High Efficiency commercial air filter can be easily mounted at the fresh air duct, return air of the Air Handling Unit, Fan coil Unit and others. Multiple units interconnected for easy form of arrays. The unit is specially designed for energy saving by using the AHU or FCU blower to draw contaminated air and trap it at the Heavy Duty Commercial cell. This front loading unit is designed for easy service maintenance. | - | Capacity up to 2000 cfm (3400m³/hr) per unit | - | Multiple units interconnected to form array of air cleaners | - | May be connected to building management system | - | Removes airborne particles as small as 0.01 micron | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Test button checks system operation | | Technical Specifications : | | | | | Honeywell | | | F58G | | | Duct Mounted | | | 2 Heavy Duty Commercial Cells | | Sensor | Air Flow Switch Relay | | | 2000 cfm (3400 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V/50Hz, Max 36W | | | GI Steel | | | 670(W) x 610(H) x 171(D) | | | 16.8 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Return Grille Mounted F58H |  | | The F58H Duct / AHU Mount Electronic Air Cleaner. The Honeywell Model F58H is design for compact and easy installation. This High Efficiency commercial air filter can be easily mounted at the fresh air duct, return air of the Air Handling Unit, Fan coil Unit and others. Multiple units interconnected for easy form of arrays. The unit is specially designed for energy saving by using the AHU or FCU blower to draw contaminated air and trap it at the Heavy Duty Commercial cell. This front loading unit is designed for easy service maintenance. | - | Capacity up to 1000 cfm (1700m³/hr) per unit | - | Multiple units interconnected to form array of air cleaners | - | May be connected to building management system | - | Removes airborne particles as small as 0.01 micron | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Test button checks system operation | | Technical Specifications : | | | | | Honeywell | | | F58H | | | Duct Mounted | | | 1 Heavy Duty Commercial Cells | | Sensor | Air Flow Switch Relay | | | 1000 cfm (1700 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V/50Hz, Max 36W | | | GI Steel | | | 670(W) x 610(H) x 171(D) | | | 10.9 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Return Duct Mounted F300A | .jpg) | | The F300A Duct / AHU Mount Electronic Air Cleaner. The Honeywell Model F300A is design for compact and easy installation. This high Efficiency commercial air filter can be easily mounted at the fresh air duct, return air of the Air Handling Unit, Fan coil Unit and others. The unit is specially designed for energy saving by using the AHU or FCU blower to draw contaminated air and trap it at the Heavy Duty Commercial cell. The side loading unit is designed for space conscious AHU room. | - | Capacity up to 2000 cfm (3400m³/hr) per unit | - | Removes airborne particles as small as 0.01 micron | - | Electronic cells can be washed in most home dishwashers | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Pressure drop is approximately equal to that of a regular fiberglass |
| filter | | Technical Specifications : | | | | | Honeywell | | | F300A (F58F) | | | Duct Mounted | | Sensor | Air Flow Switch Relay | | | 2000 cfm (3400 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V 50/60Hz, Max 36W | | | GI Steel | | | 538(W) x 648(H) x 172(D) | | | 16.8 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL Certified | | | | | | Commercial Air Cleaning Systems > Honeywell Return Duct Mounted F300B | .jpg) | | The F300B Duct Mount Electronic Air Cleaner. The Honeywell Model F300B is design for compact and easy installation. This high Efficiency commercial air filter can be easily mounted at the fresh air duct, return air of the Air Handling Unit, Fan coil Unit and others. The unit is specially designed for energy saving by using the FCU blower to draw contaminated air and trap it at the Heavy Duty Commercial cell. The side loading unit is designed for space conscious FCU unit. | - | Capacity up to 1000 cfm (1700m³/hr) | - | Removes airborne particles as small as 0.01 micron | - | Electronic cells can be washed in most home dishwashers | - | Solid state power supply self-regulating and maintains peak efficiency |
| during a wide range cell-dirt loading conditions | - | Pressure drop is approximately equal to that of a regular fiberglass |
| filter | | Technical Specifications : | | | | | Honeywell | | | F300B (F50F) | | | Duct Mounted | | Sensor | Air Flow Switch Relay | | | 1000 cfm (1700 m³/hr) | | | Up to 95% ASHRAE 52-1-1991 | | | 220-240V 50/60Hz, Max 22W | | | GI Steel | | | 318(W) x 605(H) x 172(D) | | | 9.5 kg | | | Yes (Optional) | | | 8140V d.c. | | | UL Certified | | | |