When the unit goes on, the inlet valve opens and cylinder fills of water. Water enters the bottom of the boiler and rises until it reaches the high level electrode. The electric current by applying power to electrodes immersed in water, heats the water to produce steam in response to the humidistat's input signal. The quantity of steam produced is proportional to the electric current, which is proportional to the level of water. Due to evaporation, the water level decreases and gets more conductive meaning that the water has to be replaced. 
 
Features
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production is pure, sterile and free of minerals
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif No risk of contamination by bacteria with anti freeze option
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam output from 5 to 90 Kg/Hrs
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Can be used with tap, soft, RO and DI water
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Alpha digital control panel in standard
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Drived by microprocessor with ON/OFF or proportional control
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Disposable or cleanable cylinder
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Plain stainless steel electrodes
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Recyclable plastic cylinders
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif PC board up to ROHS standard 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Front display panel message in case of failure or if cylinder needs to be changed
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Easy installation and maintenance
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Accept all common signals
 
Options
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Stainless steel manifold
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Filling cup platform
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Blower pack for direct discharge humidification
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Interface RS 485 to connect ELMC to computer
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remain temperature at 65°C
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Leakeage water detection
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Weatherproof cabinet for outdoor application
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remote information board
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif High level safety hygrostat
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Galvanic isolation 0-10V
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Upgrading kit
 
Applications
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Hospital
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Office building
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Industries
 

 
Humidifying Solutions > Devatec > Electric Steam Humidifiers > CMC
 
CMC
 
 
 
CMC Catalogue
 
CMC Technical Specification
 
 
How does it work?
When the unit goes on, the inlet valve opens and cylinder fills of water. Water enters the bottom of the boiler and rises until it reaches the high level electrode. The electric current by applying power to electrodes immersed in water, heats the water to produce steam in response to the humidistat's input signal. The quantity of steam produced is proportional to the electric current, which is proportional to the level of water. Due to evaporation, the water level decreases and gets more conductive meaning that the water has to be replaced.
 
Features
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production is pure, sterile and free of minerals
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif No risk of contamination by bacteria with anti freeze option
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam output from 1 to 4 Kg/Hrs
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Can be used with tap, soft, RO and DI water
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Drived by microprocessor with ON/OFF or proportional control
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Disposable or cleanable cylinder
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Plain stainless steel electrodes
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Recyclable plastic cylinders
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif PC board up to ROHS standard
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Easy installation and maintenance
 
Options
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Stainless steel manifold
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Filling cup platform
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Blower pack for direct space humidification
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Interface RS 485 to connect ELMC to computer
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remain temperature at 65°C
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Leakage water detection
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Weatherproof cabinet for outdoor installation
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remote information board
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Upgrading kit
 
Applications
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Museum
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Libraries
 

 
Humidifying Solutions > Devatec > Electric Steam Humidifiers > KIT MC OEM
 
KIT MC OEM
 
 
 
   
KIT MC OEM Technical Specification
 
 
How does it work?
When the unit goes on, the inlet valve opens and cylinder fills of water. Water enters the bottom of the boiler and rises until it reaches the high level electrode. The electric current by applying power to electrodes immersed in water, heats the water to produce steam in response to the humidistat's input signal. The quantity of steam produced is proportional to the electric current, which is proportional to the level of water. Due to evaporation, the water level decreases and gets more conductive meaning that the water has to be replaced. Components can be in that case directly wired.
 
Features
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production is pure, sterile and free of minerals
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif No risk of contamination by bacteria with anti freeze option
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam output from 5 to 60 Kg/Hrs
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Can be used with tap, soft and DI water
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Alpha digital control panel in standard
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Drived by microprocessor with ON/OFF or proportional control
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Disposable or cleanable cylinder
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Plain stainless steel electrodes
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Recyclable plastic cylinders
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif PC board up to ROHS standard 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Front display panel message in case of failure or if cylinder needs to be changed
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gifEasy installation and maintenance
 
Options
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Stainless steel manifold
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Interface RS 485 to connect ELMC to computer
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remain temperature at 65°C
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif ON/OFF switch or in continuous
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remote information board
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Upgrading kit
 
Applications
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif AHU manufacturer
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Oven
 

 
Humidifying Solutions > Devatec > Electric Steam Humidifiers > RTH
 
RTH
 
 
 
RTH Catalogue
 
RTH Manual & Technical Specification
 
 
How does it work?
When power is supplied to the unit, the water fill valve opens and it enters the tank until the high-water switch is reached. The humidifier then produces steam in response to the humidistat's input signal. Steam output is continuously adjusted to satisfy necessary humidity requirements.
 
Features
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production from 5 to 100 kg/h. Master slave up to 600 kg/h.
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Work with tap, soft, RO and DI water
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Alpha digital in standard with ON/OFF or proportional control in standard
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Accept all common modulating signals
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Self cleaning INCOLOY elements
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Permanent stainless tank
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Rocking tank with intermediary position allowing easy maintenance 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Cooling cycle before maintenance avoiding loosing time
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Inlet valve with internal filter 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Outlet valve with large orifice for easy scale elimination 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Possibility to maintain temperature at 80°C 
 
Options
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Possibility to link RTH to BMS control 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Remote information board - Dry contact
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Stainless steel pipe with drain tube or multi dispersion tube
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Weather proof cabinet
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Blower pack for direct discharge
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif High level safety humidistat and humidity sensor
 
Applications
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Hospital
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Office building
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Industries
 

 
Humidifying Solutions > Devatec > Electric Steam Humidifiers > Humidiclean HC6000
 
Humidiclean HC6000
 
 
 
   
HC6000 Catalogue & Technical Specification
 
 
How does it work?
When power is supplied to the unit, the water fill valve opens and it enters the tank. Once the level reaches the low-water switch, the heating elements are energized (assuming there's a call for steam output). The unit continues to fill until the high-water switch is reached. The humidifier then produces steam in response to the humidistat's input signal. Periodic tank drainage is based on active time of the heating elements, but may be field-adjusted to water conditions.
 
The HumidiClean power module accepts a proportional signal and, in response, pulses power to the heating elements to provide fully modulated output. Steam output is continuously adjusted to satisfy necessary humidity requirements.
 
Features
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production is pure, sterile and free of minerals
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif No risk of bacteria with standard aquastat
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Steam production from 4.1 to 130 Kg/Hrs
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Can be worked  with tap, soft, RO and DI water
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Alpha digital in standard
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Drived by microprocessor with proportional control
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Easy maintenance with the system Ionic Bed which reduced the deposit of minerals in the tank and also on the heating elements
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Password protected programmable keypad 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Diagnostic indicating LCD display 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Continual checking diagnostic routines 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif High and low water level detection 
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Possibility to link Humidiclean to a computer via RS485
 
Options
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Blower pack for direct discharge humidification
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif BACnet or LonWorks protocols
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Stainless steel manifold
 
Applications
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Hospital
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Office building
http://www.devatec.com/humidity/img/spacer.gifhttp://www.devatec.com/humidity/img/MenuLeft_fleche_grise.gif Industries